Dec 18, 2011

Gas cutting - Two workers burnt and four injured during the fire

It is reported that two workers died and four more were injured during gas cutting of an abandoned chemical plant machinery in a resultant fire. The chemical factory not in use for two years was purchased and renovation work was taken up. While cutting the big machinery with gas cutters, the sparks fell on the plastic boxes nearby that contained residual chemicals and quick spread of fire caused the deaths and injuries. The fire was brought under control after four hours of struggle.

To avoid such incidents, ensure:
  1. equipment free from chemicals/combustibles inside and outside
  2. absence of all combustibles/ inflammable atleast within 15 m radius of proposed hot work to avoid flying sparks falling on these materials
  3. sufficient pressure in oxygen and cutting gas cylinders
  4. good condition of hoses, torches
  5. flashback arrestors in both hose lines
  6. use of friction lighter
  7. clear means of access/egress
  8. availability of minimum numbers of extinguishers
  9. sufficient illumination and ventilation
  10. training
  11. supervision, etc